IEG Pollutant Sources & Exposures
Indoor sorption of surrogates for sarin and related nerve agents." Environmental Science & Technology 39.9 (2005) 3203–3214.
, , , , , and . "Algorithm for rapid tomography of gas concentrations." Atmospheric Environment 35 (2000) 2827–2835.
, , , and . "Rapid Measurement and Mapping of Tracer Gas Concentrations in a Large Indoor Space." Atmospheric Environment 35 (2001) 2837–2844.
, , , , , , , and . "Tracer Gas Transport under Mixed Convection Conditions in an Experimental Atrium: Comparison Between Experiments and CFD Predictions." Atmospheric Environment 40 (2006) 5236–5250.
, , , , , , , and . "Filter loading corrections for real-time aethalometer measurements of fresh diesel soot. (2007)." Journal of Air and Waste Management Association 57.7 (2007) 868–873.
, , , , and . " , , , and . "
Mixing of a Point Source Indoor Pollutant by Forced Convection." Indoor Air 5.3 (1995) 204–215.
, , , and . "Factors Affecting Indoor Air Concentrations of Volatile Organic Compounds at a Site of Subsurface Gasoline Contamination." Environmental Science and Technology 30.10 (1996) 2948–2957.
, , , , , , and . "Formaldehyde and Other Volatile Organic Chemical Emissions in Four FEMA Temporary Housing Units." Environmental Science and Technology 43 (2009) 5626–5632.
, , , and . "Soil-Gas Entry Into Houses Driven By Atmospheric Pressure Fluctuations -- the Influence of Soil Properties." Atmospheric Environment 31 (1997) 1487–1495.
, , and . "Soil gas entry into an experimental basement driven by atmospheric pressure fluctuations, measurements, spectral analysis, and model comparison." Atmospheric Environment 31 (1996) 1477–1485.
, , and . "Radon Entry into Buildings Driven by Atmospheric Pressure Fluctuations." Environmental Science & Technology 31 (1997) 1742–1748.
, and . "Measurement of Radon Decay Products in Air by Alpha- and Beta-Spectrometry." Radiation Protection Dosimetry 72 (1997) 43–48.
, and . "Regional and National Estimates of the Potential Energy Use, Energy Cost, and CO2 Emissions Associated with Radon Mitigation by Sub-Slab Depressurization." Energy and Buildings 24 (1996) 203–212.
, , and . "Effects of variable wind speed and direction on radon transport from soil into buildings: model development and exploratory results." Atmospheric Environment 33.14 (1999) 2157–2168.
, , , and . "Wind-induced Ground Pressures Around a Single-family House." Journal of Wind Engineering and Industrial Aerodynamics 61 (1995) 153–167.
, , and . "The Effect of Steady Winds on Radon Entry into Houses." Atmospheric Environment 30 (1996) 1167–1176.
, , , and . "The Influence of a Subslab Gravel Layer and Open Area on Soil-Gas and Radon Entry into Two Experimental Basements." Health Physics 69 (1995) 367–377.
, and . "Direct measurements of soil-gas entry into an experimental basement driven by atmospheric pressure fluctuations." Geophysical Research Letters 22 (1995) 1929–1932.
, and . "Scale Dependence of Soil Permeability to Air: Measurement Method and Field Investigation." Water Resources Research 32.3 (1996) 547–560.
, , , , , and . "