Implementation of VOC Source Reduction Practices in a Manufactured House and in School Classrooms

Publication Type
Conference Paper
Authors
LBL Report Number
LBNL-49536
Abstract

Detailed studies of a new manufactured house and four new industrialized relocatable school classrooms were conducted to determine the emission sources of formaldehyde and other VOCs and to identify and implement source reduction practices. Procedures were developed to generate VOC emission factors that allowed reasonably accurate predictions of indoor air VOC concentrations. Based on the identified sources of formaldehyde and other aldehydes, practices were developed to reduce the concentrations of these compounds in new house construction. An alternate ceiling panel reduced formaldehyde concentrations in the classrooms. Overall, the classrooms had relatively low VOC concentrations.

Conference Name
Indoor Air 2002, June 30 - July 5, 2002
Volume
3
Year of Publication
2002
Pagination
576-581
Conference Location
Monterey, California
Keywords
Organizations
Research Areas
File(s)
Download citation