Particle Penetration Through Windows

Publication Type
Conference Proceedings
Authors
Abstract

This study aims to characterize the fractional penetration of airborne particles through windows, one of the important sites of air leakage through building envelopes. Two aluminum windows were evaluated, one with weatherstripping and one without. For each experiment, a finished window was mounted and sealed in a plywood panel that separated two well-mixed compartments. A small pressure difference was established between the compartments to induce a constant rate of airflow through leakage paths in the window. Particles were injected into one chamber and their concentrations were measured in both chambers. Two methods were employed to evaluate the size-resolved particle penetration: a steady-state method and a dynamic, concentration growth method. The results indicate that airborne particles of 0.2 to 3 ?m penetrate through both test windows fairly effectively, while significant particle losses are observed for particles smaller and larger than this range.

Conference Name
Proceedings of the Indoor Air 2002 Conference, Monterey, CA
Volume
1
Year of Conference
2002
Pagination
862-867
Publisher
Indoor Air 2002, Santa Cruz, CA
Organizations
Research Areas
Download citation