A Method of Optimizing Solar Control and Daylighting Performance in Commercial Office Buildings
| Date Published |
12/1992
|
|---|---|
| Publication Type | Conference Paper
|
| Authors | |
|---|---|
| LBL Report Number |
LBL-32931
|
| Abstract |
We present a method for analyzing the annual cooling and lighting electricity use and peak demand associated with varying fenestration and lighting strategies in commercial office buildings. A prototypical office building module consisting of four perimeter zones and a central core zone was defined and a series of DOE-2 bidding energy simulations were completed to create a data base for varying fenestration and lighting system parameters. Using regression analysis procedures, we characterize electric energy and peak performance patterns as a function of solar aperture, defined as the product of shading coefficient and window-to-wall ratio, and efective daylighting aperture, defined as the product of visible transmittance and window-to-wall ratio. Optimum performance consists of defining the solar and effective daylighting aperture values that minimize annual energy consumption and peak demand, a process easily facilitated by the methods described herein. |
| Proceedings Title |
Thermal Performance of the Exterior Envelopes of Buildings V Conference
|
| Conference Name |
Thermal Performance of the Exterior Envelopes of Buildings V Conference
|
| Year of Publication |
1992
|
| Conference Location |
Clearwater Beach, FL
|
| Call Number |
LBL-32931
|
| Custom 1 |
<p>Windows and Daylighting Group</p>
|
| Organizations | |
| Research Areas | |
| File(s) | |
| Download citation |