Method of Measuring Nighttime U-Values Using the Mobile Window Thermal Test (MoWiTT) Facility

Date Published
06/1992
Publication Type
Journal Article
Author
LBL Report Number
LBL-30032
Abstract

Although primarily designed for studying the dynamic net energy flows through fenestration systems over the full diurnal cycle, the Mobile Window Thermal Test (MoWiTT) Facility is also frequently used to measure nighttime U-values. These measurements have the advantage of incorporating the exterior film coefficient resulting from the true ambient conditions at a particular time and location, rather than relying on a laboratory simulation of some assumed average or extreme condition. On the other hand, the MoWiTT is a much more complicated facility than a laboratory hot box, and the number of potential error sources is correspondingly larger. The method of deriving the nighttime U-value from directly measured data and the effect of random and systematic errors are discussed.

Journal
ASHRAE Transactions
Volume
98, Part 2
Year of Publication
1992
Place Published
Baltimore, MD
Call Number
LBL-30032