Gas Water Heater Energy Losses
| Date Published |
01/2009
|
|---|---|
| Publication Type | Report
|
| Authors | |
|---|---|
| LBL Report Number |
LBNL-4826E
|
| Abstract |
A forty gallon residential gas-fired storage water heater was modeled under Department of Energy test procedure conditions using the TANK simulation program. The purpose was to determine heat flows in a typical residential storage water heater that meets the current minimum efficiency standards. Modeling showed that, without considering a condensing water heater design, the greatest potential efficiency gains can be made by reducing flue losses during the non-firing, non-recovery mode, i.e., during standby mode. The stack losses while in standby mode account for about 43% of heat losses (not including the energy added to deliver hot water), and 17% if hot water energy is included. |
| Year of Publication |
2009
|
| Pagination |
20
|
| Institution |
Lawrence Berkeley National Laboratory
|
| City |
Berkeley
|
| ISBN Number |
LBNL-4826E
|
| Organizations | |
| Research Areas | |
| File(s) | |
| Download citation |