Fluorescent Lamp Fixtures and Ballasts
Date Published |
05/1984
|
---|---|
Publication Type | Conference Paper
|
Author | |
---|---|
LBL Report Number |
LBL-17929
|
Abstract |
This paper discusses the basic parameters of a fluorescent lighting system that affect the illumination level. The parameters include the thermal performance of the fixture and the ballast factor, voltage regulation, and thermal regulation of the ballast/lamp system. Fixtures determine the minimum lamp-wall temperature of the lamps and are described as hot or cold. That is, the lamp-wall temperatures can vary from 39 to 61 °C. In general, cool fixtures tend to provide higher light levels and are more efficacious for a given ballast/lamp system. Solid-state fluorescent ballast/lamp systems have been measured and show a variation in light output from 6170 to 3780 lumens for the two-lamp, F-40, T-12, rapid-start lamps. Lighting designers must obtain this information in order to accurately predict illumination levels in a space. |
Conference Name |
EPRI Lighting and Utility Seminar
|
Year of Publication |
1984
|
Conference Location |
San Francisco, CA
|
Call Number |
LBL-17929
|
Custom 1 |
<p>Lighting Systems Group</p>
|