Experimental validation for thermal transmittances of window shading systems with perimeter gaps

Date Published
02/2018
Publication Type
Journal Article
Authors
DOI
10.1080/19401493.2018.1436192
Abstract

Virtually all residential and commercial windows in the U.S. have some form of window attachment, but few have been designed for energy savings. ISO 15099 presents a simulation framework to determine thermal performance of window attachments, but the model has not been validated for these products. This paper outlines a review and validation of the ISO 15099 centre-of-glass heat transfer correlations for perimeter gaps (top, bottom, and side) in naturally ventilated cavities through measurement and simulation. The thermal transmittance impact due to dimensional variations of these gaps is measured experimentally, simulated using computational fluid dynamics, and simulated utilizing simplified correlations from ISO 15099. Results show that the ISO 15099 correlations produce a mean error between measured and simulated heat flux of 2.5 +/- 7 percent. These tolerances are similar to those obtained from sealed cavity comparisons and are deemed acceptable within the ISO 15099 framework.

Journal
Journal of Building Performance Simulation
Year of Publication
2018
Pagination
1 - 13
ISSN Number
1940-1493
Short Title
Journal of Building Performance Simulation
Organizations
Research Areas
File(s)
Download citation