Estimation of Infiltration from Leakage and Climate Indicators
Date Published |
01/1986
|
---|---|
Publication Type | Journal Article
|
Author | |
---|---|
LBL Report Number |
LBL-21463
|
Abstract |
A simple model is developed for the estimation of annual infiltration rates in single- family houses using indicators for both house tightness (air changes at 50 Pa) and site climate (the leakage-infiltration ratio). This technique is best suited to low-accuracy, large dataset problems where detailed data are not available. The method is similar to the method attributed to Kronvall and Persily (i.e. the K-P method), but is derived from a physical model, the LBL infiltration model. The estimation technique is developed assuming a typical, single-story dwelling; correction factors for common variations in building and environmental conditions are tabulated. A map of the leakage-infiltration ratio in the U.S. for the reference case is also presented. |
Journal |
Energy and Buildings
|
Volume |
10
|
Year of Publication |
1986
|
Pagination |
81-86
|
Keywords | |
Organizations | |
File(s) | |
Download citation |