Error Analysis of In-Situ Field Tests of Fenestration Performance
Publication Type | Journal Article
|
---|
Author | |
---|---|
LBL Report Number |
LBL-18198
|
Abstract |
The need for information about fenestration net energy performance under realistic conditions is discussed and the method of measuring it in a field test on a complete building is reviewed. A detailed consideration of the energy flows entering the energy balance on a building space adjacent to a fenestration system and the effect of random measurement errors on the determination of fenestration performance is presented. Estimates of the error magnitudes are made for prototypical field tests utilizing a residential and a moderate-sized commercial building. In both cases, it is shown that these errors make it difficult to isolate the fenestration performance even for relatively low-performance windows (1-2 times the resistance of single glazing). It is concluded that whole-building measurements are not well adapted to measuring the performance of advanced fenestration system (thermal resistance 2-10 times that of single glazing or shading coefficient less than 0.7). |
Journal |
Energy and Buildings
|
Volume |
8
|
Year of Publication |
1984
|
Number |
3
|
Pagination |
165-173
|
Call Number |
LBL-18198
|
Custom 1 |
<p>Windows and Daylighting Group</p>
|
Organizations | |
Research Areas | |
File(s) | |
Download citation |