The Effects of Skylight Parameters on Daylighting Energy Savings

Publication Type
Report
Authors
LBL Report Number
LBL-17456
Abstract

Skylight parameters that affect lighting, cooling, heating, fan, and total energy use in office buildings are examined using the state-of-the-art building energy analysis computer code, DOE-2.1B. The lighting effects of skylight spatial distribution, skylight area, skylight visible transmission, well factor, illumination setpoint, interior partitions, ceiling height, and glazing characteristics are discussed. This study serves as the foundation for the creation of a DOE-2.1B database and design tools for estimating daylighting energy savings from skylights.

Year of Publication
1985
Call Number
LBL-17456
Custom 1
<p>Windows and Daylighting Group</p>
Organizations
Research Areas
File(s)