%0 Journal Article %A Rudolph R Verderber %A Oliver C Morse %B Electrical Construction and Maintenance %D 1980 %G eng %L LBL-10789 %T Cost Effectiveness of Long Life Incandescent Lamps and Energy Buttons %V 80 %1
Lighting Systems Group
%2 LBL-10789 %XLong-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen hours are determined for each lamp system. We find the most important component lighting cost is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial unit cost of $20.00, is the most cost-effective source of illumination compared to the incandescent lamp and lamp systems examined.