TY - CPAPER AU - Haoran Zhao AU - Wanyu R Chan AU - Chrissi Antonopoulos AU - Eric Martin AU - Paul Francisco AU - Iain S Walker AU - Brett C Singer AB -

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor
air quality (IAQ) in 139 homes across four US regions, including 29 in the Marine climate of
Oregon, 26 in Cold-Dry Colorado, 32 in Mixed-Humid Illinois, and 52 in the Hot-Humid
Southeast. Thirty-six homes were monitored with and without WHMV operating. All homes
had operational cooktop ventilation and bathroom exhaust. Envelope and duct airtightness;
mechanical ventilation airflows; time-resolved CO2, PM2.5 formaldehyde and radon; and time-
integrated NO2, NOx and formaldehyde were measured. Participants provided information
about IAQ-impacting activities, perceptions and ventilation use. Preliminary results indicate
that the installed WHMV often did not meet requirements of ASHRAE 62.2-2010; WHMV
was operating in only half of the homes as found and 22% had WHMV airflow at or above the
requirement, as found. Homes with WHMV had significantly lower CO2 and radon
concentrations compared to those without WHMV running

BT - Indoor Air 2024 DA - 04/2024 LA - eng N2 -

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor
air quality (IAQ) in 139 homes across four US regions, including 29 in the Marine climate of
Oregon, 26 in Cold-Dry Colorado, 32 in Mixed-Humid Illinois, and 52 in the Hot-Humid
Southeast. Thirty-six homes were monitored with and without WHMV operating. All homes
had operational cooktop ventilation and bathroom exhaust. Envelope and duct airtightness;
mechanical ventilation airflows; time-resolved CO2, PM2.5 formaldehyde and radon; and time-
integrated NO2, NOx and formaldehyde were measured. Participants provided information
about IAQ-impacting activities, perceptions and ventilation use. Preliminary results indicate
that the installed WHMV often did not meet requirements of ASHRAE 62.2-2010; WHMV
was operating in only half of the homes as found and 22% had WHMV airflow at or above the
requirement, as found. Homes with WHMV had significantly lower CO2 and radon
concentrations compared to those without WHMV running

PY - 2024 T2 - Indoor Air 2024 T3 - Indoor Air 2024 TI - Mechanical Ventilation and IAQ in Recently Constructed US Homes ER -