TY - JOUR KW - Bayesian updating KW - Fault detection and diagnosis KW - Chiller plant faults KW - Unscented Kalman filtering AU - Marco Bonvini AU - Michael D Sohn AU - Jessica Granderson AU - Michael Wetter AU - Mary Ann Piette AB -

This work presents a robust and computationally efficient algorithm for both whole-building and component-level energy fault detection and diagnosis (FDD). The algorithm is able to provide reliable estimation of multiple and simultaneous fault conditions, even in the presence of noisy and sometimes erroneous sensor data, and to provide uncertainty estimation. The algorithm can be used to provide such outputs as the probability of a fault, the likely cause(s), and the expected consequences of the fault(s) on energy use. The approach is based on an advanced Bayesian nonlinear state estimation technique called Unscented Kalman Filtering, but with our addition of a back-smoothing method that provides fast and robust FDD for common building use cases. The approach is presented and demonstrated for detecting energy and hydraulic faults in a chiller plant. The model of the chiller plant is a subsystem of an actual chiller plant, calibrated to real data. The algorithm can detect common faults, such as (1) energy faults (e.g., the chiller is not working properly, or far from its nominal condition), (2) functional faults caused by issues in the compressor and (3) occlusions in the valves that may reduce the water flow rate through the condenser and evaporator water loop. It is also shown that estimates of uncertainty are consistent with the error in the synthetic data, and can be updated as new data stream in from sensors.

BT - Applied Energy DA - 07/2014 DO - 10.1016/j.apenergy.2014.03.009 LA - eng N2 -

This work presents a robust and computationally efficient algorithm for both whole-building and component-level energy fault detection and diagnosis (FDD). The algorithm is able to provide reliable estimation of multiple and simultaneous fault conditions, even in the presence of noisy and sometimes erroneous sensor data, and to provide uncertainty estimation. The algorithm can be used to provide such outputs as the probability of a fault, the likely cause(s), and the expected consequences of the fault(s) on energy use. The approach is based on an advanced Bayesian nonlinear state estimation technique called Unscented Kalman Filtering, but with our addition of a back-smoothing method that provides fast and robust FDD for common building use cases. The approach is presented and demonstrated for detecting energy and hydraulic faults in a chiller plant. The model of the chiller plant is a subsystem of an actual chiller plant, calibrated to real data. The algorithm can detect common faults, such as (1) energy faults (e.g., the chiller is not working properly, or far from its nominal condition), (2) functional faults caused by issues in the compressor and (3) occlusions in the valves that may reduce the water flow rate through the condenser and evaporator water loop. It is also shown that estimates of uncertainty are consistent with the error in the synthetic data, and can be updated as new data stream in from sensors.

PY - 2014 SP - 156 EP - 166 ST - Applied Energy T2 - Applied Energy TI - Robust on-line fault detection diagnosis for HVAC components based on nonlinear state estimation techniques VL - 124 SN - 03062619 ER -