TY - CPAPER AU - Francis M Rubinstein AU - Chin Zhang AB -

A spreadsheet program for determining system efficacy, power input and light output of common 4 ft fluorescent lighting systems under realistic operating conditions is described. The program uses accepted IES engineering principles to precisely account for ballast factor, existing thermal conditions and maintenance practices. The spreadsheet, which includes a data base of lamp and ballast performance data, can be used to calculate the cost-effectiveness of many common lighting retrofits.

BT - Illuminating Engineering Society Annual Conference 1991 C1 -

Lighting Systems Group

C2 - LBL-30648 CN - LBL-30648 CY - Montreal, Canada DA - 08/1991 LA - eng N2 -

A spreadsheet program for determining system efficacy, power input and light output of common 4 ft fluorescent lighting systems under realistic operating conditions is described. The program uses accepted IES engineering principles to precisely account for ballast factor, existing thermal conditions and maintenance practices. The spreadsheet, which includes a data base of lamp and ballast performance data, can be used to calculate the cost-effectiveness of many common lighting retrofits.

PP - Montreal, Canada PY - 1991 T2 - Illuminating Engineering Society Annual Conference 1991 T3 - Illuminating Engineering Society Annual Conference 1991 TI - A Spreadsheet for Analyzing the In-Situ Performance of Fluorescent Luminaries ER -