TY - CPAPER AU - Brent T Griffith AU - Dariush K Arasteh AB -

This paper discusses the use of gas-filled panel technology as a high-performance, non-CFC insulation for building applications. Gas-filled panels (GFPs) combine low-emissivity surfaces and multiple, low-conductivity gas-filled cavities to minimize radiation, convection, and conduction. The thermal performance of some GFP designs has been independently tested (ASTM 1989) at a national laboratory. Measurements on first-generation prototypes yielded R-5.2/in. (5.2 h ft2 °F/Btu in. [36 m.K/W]) with an air fill, R-7.1/in. (49.3 m K/W) with an argon fill, and R-12.5/in. (86.8 m K/W) with a krypton fill. This paper discusses technical aspects of GFP barrier materials and their gas transmission rate requirements, baffle component characteristics, and potential gas fills. We present examples of potential GFP products for various building applications with cost and performance estimates.

BT - Proceedings of the Thermal Performance of the Exterior Envelopes of Buildings V Conference C1 -

Windows and Daylighting Group

C2 - LBL-33191 CN - LBL-33191 CY - Clearwater Beach, FL DA - 12/1992 LA - eng N2 -

This paper discusses the use of gas-filled panel technology as a high-performance, non-CFC insulation for building applications. Gas-filled panels (GFPs) combine low-emissivity surfaces and multiple, low-conductivity gas-filled cavities to minimize radiation, convection, and conduction. The thermal performance of some GFP designs has been independently tested (ASTM 1989) at a national laboratory. Measurements on first-generation prototypes yielded R-5.2/in. (5.2 h ft2 °F/Btu in. [36 m.K/W]) with an air fill, R-7.1/in. (49.3 m K/W) with an argon fill, and R-12.5/in. (86.8 m K/W) with a krypton fill. This paper discusses technical aspects of GFP barrier materials and their gas transmission rate requirements, baffle component characteristics, and potential gas fills. We present examples of potential GFP products for various building applications with cost and performance estimates.

PP - Clearwater Beach, FL PY - 1992 T2 - Proceedings of the Thermal Performance of the Exterior Envelopes of Buildings V Conference T3 - Thermal Performance of the Exterior Envelopes of Buildings V Conference TI - Gas-Filled Panels: A Thermally Improved Building Insulation ER -