TY - CPAPER AU - Michael J Siminovitch AU - Francis M Rubinstein AU - Rudolph R Verderber AB -

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed.

BT - IEEE-IAS Annual Conference C1 -

Lighting Systems Group

C2 - LBL-22531 CN - LBL-22531 CY - Toronto, Canada DA - 10/1985 LA - eng N2 -

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed.

PP - Toronto, Canada PY - 1985 T2 - IEEE-IAS Annual Conference T3 - IEEE-IAS Annual Conference TI - Fixture Conditions Affect Lamp Performance ER -