TY - RPRT KW - Energy efficiency KW - China KW - Room air conditioners KW - Round robin testing AU - Nan Zhou AU - David Fridley AU - Nina Zheng AU - André Pierrot AU - Nina Khanna AB -

The main conclusions of the studies are the following ones:

In our opinion, it is possible to enhance the quality of the testing without excessive efforts,provided that some periodic verification is performed within the independent laboratories. We would also like to point out that the air enthalpy method is not the best test method in a MEPS environment, as this method has a greater uncertainty of measurement than the calorimeter room method, and above all because there is no verification of the result with a simultaneous measurement outdoor side.

DA - 06/2010 LA - eng N2 -

The main conclusions of the studies are the following ones:

In our opinion, it is possible to enhance the quality of the testing without excessive efforts,provided that some periodic verification is performed within the independent laboratories. We would also like to point out that the air enthalpy method is not the best test method in a MEPS environment, as this method has a greater uncertainty of measurement than the calorimeter room method, and above all because there is no verification of the result with a simultaneous measurement outdoor side.

PB - Lawrence Berkeley National Laboratory; The Japan Refrigeration and Air Conditioning Industry Association PY - 2010 TI - China Energy Efficiency Round Robin Testing Results for Room Air Conditioners ER -