@misc{35954, keywords = {windows, structural, Thin glass, IGU, Nonfactored load}, author = {Robert Hart and Stephen Fisher and Stephen Morse}, title = {Guidelines for Determining the Load Resistance of Thin-Glass Triple-Pane Insulating Glass Unit Configurations}, abstract = {

This guideline is intended to provide information relevant to the specification of triple- pane insulating glass (IG) units where the thickness of lite number 2 (center lite) is less than or equal to the thickness of lite numbers 1 and 3. Procedures and charts are presented to determine the load resistance (LR) of common soda-lime glass thicknesses from 0.7 mm (3/128 in.) to 1.8 mm (9/128 in.) exposed to a uniform lateral load of short or long duration, for a 0.008 probability of breakage. Deflection under load, horizontal self-weight deflection, and natural frequency procedures and charts are also included to aide in the selection of glass thickness to meet manufacturing and/or loading criteria determined by the user.

}, year = {2023}, issn = {LBNL-2001536}, url = {https://escholarship.org/uc/item/55w3r37w}, doi = {https://doi.org/10.20357/B7SS35}, language = {eng}, }