@article{25323, keywords = {Comparison, Spectroscopy, Absorption, Probe}, author = {Richard A Torres and Cynthia E. A Palmer and Patricia A Baisden and Robert J Silva and Richard E Russo}, title = {Comparison of photoacoustic spectroscopy, conventional absorption spectroscopy, and potentiometry as probes of Lanthanide speciation}, abstract = {

We measured the stability constants of praseodymium acetate and oxydiacetate complexes by laser-induced photoacoustic spectroscopy, conventional UV-visible absorption spectroscopy, and pH titration. For the spectroscopic studies, changes in the free Pr absorption peaks at 468 and 481 nm were monitored at varying ligand concentrations. The total Pr concentration was 1 X 10-4 M in solutions used for the photoacoustic studies and 0.02 M for conventional spectroscopy. For the pH titrations, we used solutions whose Pr concentrations varied from 5 X 10-3 M to 5 X 10-2 M, with total ligand-to-metal ratios ranging from 1 to 10. A comparison of the results obtained by the three techniques demonstrates that photoacoustic spectroscopy can give the same information about metal-ligand speciation as more conventional methods. It is particularly suited to those situations where the other techniques are insensitive because of limited metal concentrations.

}, year = {1990}, journal = {Analytical Chemistry}, volume = {62}, pages = {298-303}, month = {02/1990}, doi = {10.1021/ac00202a014}, note = {

NOT IN FILE