@inproceedings{23819, author = {Rudolph R Verderber and Oliver C Morse and Francis M Rubinstein and Michael J Siminovitch}, title = {Measurement of Optical Efficiency of Fluorescent Luminaires}, abstract = {
By controlling the lamp wall temperature of fluorescent lamps with a Peltier device, the optical efficiency of luminaires can be measured directly. Measurements of the fixture efficiency for a luminaire can vary by over 8% depending upon the lamp-ballast system used in the measurement. The authors suggest that optical efficiency may besan improved metric for evaluating fixture designs.
}, year = {1987}, journal = {1987 IES National Conference}, month = {08/1987}, address = {Scottsdale, AZ}, language = {eng}, }