@article{22119, keywords = {Formaldehyde, Aldehydes, Emissions, Houses, Source reduction, Wood products}, author = {Alfred T Hodgson and David Beal and Janet E.R McIlvaine}, title = {Sources of Formaldehyde, Other Aldehydes and Terpenes in a New Manufactured House}, abstract = {

Formaldehyde, less volatile aldehydes, and terpene hydrocarbons are generally the predominant air contaminants in new manufactured and site-built houses. This study was conducted to identify the major sources of these compounds in a typically constructed, new manufactured house and to evaluate several source reduction practices. Specimens of materials used within the house were collected. These were individually pre-conditioned for 19 ± 4 days, and tested for emissions of formaldehyde and other target compounds using small-scale chambers. Several cabinetry materials, passage doors, and the plywood subfloor were the predominant sources of formaldehyde and other aldehydes. The plywood subfloor was the predominant terpene source. Whole-house emission rates for combined materials were predicted based on the emission factors and the corresponding material quantities. These predicted rates were compared with whole-house emission rates derived from measurements made at the house 3 months after its installation. For 10 of 14 target compounds including formaldehyde, the predicted and derived rates were within a factor of two. Four emission barriers applied to plywood were shown to reduce emission factors for formaldehyde, hexanal, and other aldehydes.

}, year = {2002}, journal = {Indoor Air}, volume = {12}, number = {4}, pages = {235-242}, month = {12/2002}, doi = {10.1034/j.1600-0668.2002.01129.x}, language = {eng}, }